產(chǎn)品中心

            人淀粉樣蛋白β1-40(Ab1-40)酶聯(lián)免疫吸附檢測試劑盒
            ELK1492
            規(guī)格: 價格:
            48T ¥1960.00
            96T ¥2800.00

            Overview

            Product name: Human Ab1-40(Amyloid Beta Peptide 1-40) ELISA Kit
            Reactivity: Human
            Alternative Names: Amyloid Beta Peptide 1-40
            Assay Type: Sandwich
            Sensitivity: 4.48 pg/mL
            Standard: 1000 pg/mL
            Detection Range: 15.63-1000 pg/mL
            Sample Type: Serum, plasma and other biological fluids
            Assay Length: 3.5h
            Research Area: Infection immunity;Neuro science;
            Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human Ab1-40. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human Ab1-40. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human Ab1-40, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human Ab1-40 in the samples is then determined by comparing the OD of the samples to the standard curve.

            標準曲線

            Concentration (pg/mL) OD Corrected OD
            1000.00 2.082 1.987
            500.00 1.621 1.526
            250.00 0.997 0.902
            125.00 0.765 0.670
            62.50 0.503 0.408
            31.25 0.351 0.256
            15.63 0.221 0.126
            0.00 0.095 0.000

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant Ab1-40 and the recovery rates were calculated by comparing the measured value to the expected amount of Ab1-40 in samples.
            Matrix Recovery range Average
            serum(n=5) 80-94% 87%
            EDTA plasma(n=5) 89-101% 95%
            Heparin plasma(n=5) 82-95% 88%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ab1-40 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 89-97% 86-102% 94-106% 85-97%
            EDTA plasma(n=5) 85-97% 93-106% 83-95% 88-103%
            Heparin plasma(n=5) 95-103% 88-96% 81-95% 91-102%