產(chǎn)品中心

            大鼠生長(zhǎng)抑素(SST)酶聯(lián)免疫吸附檢測(cè)試劑盒
            ELK1427
            規(guī)格: 價(jià)格:
            48T ¥1960.00
            96T ¥2800.00

            Overview

            Product name: Rat SST(Somatostatin) ELISA Kit
            Reactivity: Rat
            Alternative Names: GHIH; SRIF; SMST; GHRIH; GHRIF; Growth Hormone Releasing Inhibiting Hormone; Somatotropin Release-Inhibiting Factor; Somatostatin-14; Somatostatin-28
            Assay Type: Competitive Inhibition
            Sensitivity: 2.83 pg/mL
            Standard: 500 pg/mL
            Detection Range: 7.82-500 pg/mL
            Sample Type: serum, plasma and other biological fluids
            Assay Length: 2h
            Research Area: Tumor immunity;Endocrinology;Hormone metabolism;
            Uniprot ID: P60042
            Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat SST. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat SST. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat SST in the samples is then determined by comparing the OD of the samples to the standard curve.

            標(biāo)準(zhǔn)曲線

            Concentration (pg/mL) OD Corrected OD
            500.00 0.235
            250.00 0.356
            125.00 0.672
            62.50 0.897
            31.25 1.275
            15.63 1.587
            7.82 1.835
            0.00 2.316

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant SST and the recovery rates were calculated by comparing the measured value to the expected amount of SST in samples.
            Matrix Recovery range Average
            serum(n=5) 87-101% 94%
            EDTA plasma(n=5) 82-95% 88%
            Heparin plasma(n=5) 84-96% 90%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SST and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 81-97% 88-102% 85-93% 83-97%
            EDTA plasma(n=5) 86-93% 91-105% 87-98% 89-94%
            Heparin plasma(n=5) 86-93% 93-101% 86-97% 90-101%
            關(guān)閉

            在線咨詢

            Online consultation

            • 在線咨詢
            • 技術(shù)支持

            關(guān)注微信公眾號(hào)

            微信掃一掃立即咨詢

            微信掃一掃立即咨詢

            關(guān)閉
            国产美女久久精品麻豆,亚洲激情小说,国产成人在线播放视,91精品在线无毒不卡 亚洲三区无码在线 日本熟妇牲交视频在线观看,国产在线播放99,国产一级无码视频,国产在线观看添荫蒂视频|www.tjnx.com.cn/ 日本熟妇牲交视频在线观看,国产在线播放99,国产一级无码视频,国产在线观看添荫蒂视频|www.zzshanglu.com http://www.tjnx.com.cn/ http://www.zzshanglu.com