產(chǎn)品中心

            人血管內(nèi)皮鈣黏蛋白(VE-Cadherin)酶聯(lián)免疫吸附檢測(cè)試劑盒
            ELK1084
            規(guī)格: 價(jià)格:
            48T ¥1680.00
            96T ¥2400.00

            Overview

            Product name: Human VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit
            Reactivity: Human
            Alternative Names: CD144; 7B4; Cadherin 5 Type 2; VE-Cadherin; Cadherin,Vascular Endothelial; CDH5; Cadherin 5
            Assay Type: Sandwich
            Sensitivity: 29 pg/mL
            Standard: 5000 pg/mL
            Detection Range: 78.13-5000 pg/mL
            Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
            Assay Length: 3.5h
            Research Area: CD & Adhesion molecule;Tumor immunity;Infection immunity;
            Uniprot ID: P33151
            Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VE-Cadherin. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human VE-Cadherin. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human VE-Cadherin, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VE-Cadherin in the samples is then determined by comparing the OD of the samples to the standard curve.

            標(biāo)準(zhǔn)曲線

            Concentration (pg/mL) OD Corrected OD
            5000.00 2.038 1.957
            2500.00 1.407 1.326
            1250.00 0.824 0.743
            625.00 0.599 0.518
            312.50 0.347 0.266
            156.25 0.252 0.171
            78.13 0.114 0.033
            0.00 0.081 0.000

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant VE-Cadherin and the recovery rates were calculated by comparing the measured value to the expected amount of VE-Cadherin in samples.
            Matrix Recovery range Average
            serum(n=5) 83-95% 89%
            EDTA plasma(n=5) 79-93% 86%
            Heparin plasma(n=5) 92-105% 98%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VE-Cadherin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 97-105% 84-96% 87-98% 95-102%
            EDTA plasma(n=5) 79-97% 90-99% 95-103% 89-97%
            Heparin plasma(n=5) 85-94% 79-92% 87-101% 82-90%
            關(guān)閉

            在線咨詢

            Online consultation

            • 在線咨詢
            • 技術(shù)支持

            關(guān)注微信公眾號(hào)

            微信掃一掃立即咨詢

            微信掃一掃立即咨詢

            關(guān)閉
            国产美女久久精品麻豆,亚洲激情小说,国产成人在线播放视,91精品在线无毒不卡 亚洲三区无码在线 日本熟妇牲交视频在线观看,国产在线播放99,国产一级无码视频,国产在线观看添荫蒂视频|www.tjnx.com.cn/ 日本熟妇牲交视频在线观看,国产在线播放99,国产一级无码视频,国产在线观看添荫蒂视频|www.zzshanglu.com http://www.tjnx.com.cn/ http://www.zzshanglu.com