產(chǎn)品中心

            人糖蛋白130(gp130)酶聯(lián)免疫吸附檢測(cè)試劑盒
            ELK1031
            規(guī)格: 價(jià)格:
            48T ¥1680.00
            96T ¥2400.00

            Overview

            Product name: Human gp130(Glycoprotein 130) ELISA Kit
            Reactivity: Human
            Alternative Names: CDw130; CD130; IL6ST; GP130-RAPS; IR6RB; IL6R-Beta; IR6RB; IR6-RB; Interleukin 6 Signal Transducer; Oncostatin M Receptor; Interleukin-6 Receptor Subunit Beta
            Assay Type: Sandwich
            Sensitivity: 0.115 ng/mL
            Standard: 20 ng/mL
            Detection Range: 0.32-20 ng/mL
            Sample Type: Serum, plasma and other biological fluids.
            Assay Length: 3.5h
            Research Area: Signal transduction;Infection immunity;
            Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human gp130. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human gp130. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human gp130, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human gp130 in the samples is then determined by comparing the OD of the samples to the standard curve.

            標(biāo)準(zhǔn)曲線

            Concentration (ng/mL) OD Corrected OD
            20.00 2.532 2.381
            10.00 1.621 1.470
            5.00 0.935 0.784
            2.50 0.611 0.460
            1.25 0.386 0.235
            0.63 0.352 0.201
            0.32 0.203 0.052
            0.00 0.151 0.000

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant gp130 and the recovery rates were calculated by comparing the measured value to the expected amount of gp130 in samples.
            Matrix Recovery range Average
            serum(n=5) 83-97% 90%
            EDTA plasma(n=5) 80-97% 88%
            Heparin plasma(n=5) 85-101% 93%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of gp130 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 79-92% 95-103% 82-98% 85-97%
            EDTA plasma(n=5) 91-97% 86-92% 79-93% 89-106%
            Heparin plasma(n=5) 95-104% 87-96% 89-101% 82-90%