產(chǎn)品中心

            一步法大鼠游離三碘甲狀腺原氨酸(T3)酶聯(lián)免疫吸附檢測(cè)試劑盒
            ELK050ES
            規(guī)格: 價(jià)格:
            48T ¥2240.00
            96T ¥3200.00

            Overview

            Product name: EasyStep Rat fT3(Free Triiodothyronine) ELISA Kit
            Reactivity: Rat
            Alternative Names: 3,3',5-Triiodo-L-Thyronine; Liothyronine; Cytomel; Tertroxin
            Assay Type: Competitive Inhibition
            Sensitivity: 0.31 ng/mL
            Standard: 20 ng/mL
            Detection Range: 0.32-20 ng/mL
            Sample Type: Serum, plasma
            Assay Length: 1.5h
            Research Area: Endocrinology;Autoimmunity;
            Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Rat fT3 antigen, and the Rat fT3 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Rat fT3 to each microplate well and incubated . After TMB substrate solution is added, the enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ±10nm. The concentration of Rat fT3 in the samples is then determined by comparing the OD of the samples to the standard curve.

            標(biāo)準(zhǔn)曲線

            Concentration (ng/mL) OD Corrected OD
            20.00 0.235
            10.00 0.479
            5.00 0.722
            2.50 0.997
            1.25 1.236
            0.63 1.596
            0.32 1.861
            0.00 2.232

            精密度

            Intra-assay Precision (Precision within an assay):CV%<8%

            Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

            Inter-assay Precision (Precision between assays):CV%<10%

            Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

            回收率

            Matrices listed below were spiked with certain level of recombinant fT3 and the recovery rates were calculated by comparing the measured value to the expected amount of fT3 in samples.
            Matrix Recovery range Average
            serum(n=5) 92-105% 98%
            EDTA plasma(n=5) 89-103% 96%
            Heparin plasma(n=5) 88-102% 95%

            線性

            The linearity of the kit was assayed by testing samples spiked with appropriate concentration of fT3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
            Matrix 1:2 1:4 1:8 1:16
            serum(n=5) 85-94% 90-99% 95-102% 82-90%
            EDTA plasma(n=5) 85-92% 83-96% 93-102% 87-98%
            Heparin plasma(n=5) 87-90% 87-98% 85-96% 85-95%

            產(chǎn)品成分表

            關(guān)閉

            在線咨詢

            Online consultation

            • 在線咨詢
            • 技術(shù)支持

            關(guān)注微信公眾號(hào)

            微信掃一掃立即咨詢

            微信掃一掃立即咨詢

            關(guān)閉
            国产美女久久精品麻豆,亚洲激情小说,国产成人在线播放视,91精品在线无毒不卡 亚洲三区无码在线 日本熟妇牲交视频在线观看,国产在线播放99,国产一级无码视频,国产在线观看添荫蒂视频|www.tjnx.com.cn/ 日本熟妇牲交视频在线观看,国产在线播放99,国产一级无码视频,国产在线观看添荫蒂视频|www.zzshanglu.com http://www.tjnx.com.cn/ http://www.zzshanglu.com